1 Code Type Image Audio thisFrame thisSpot ToSpot Priority Elength English Slength Spanish Clength Creole 2 XCP Title Xceed ACT-1 topic Intro XceedPro Training 3 XCP Body Xceed ACT-2 Welcome to the Precision XceedPro Blood Glucose Monitoring System Operator Training Video. 4 XCP Body Xceed ACT-3 XCPMain Abbott Diabetes Care created this guide to describe how to collect blood samples and perform patient tests and control tests using the Precision XceedPro System. 5 XCPMain Title Xceed XCP menu XCPMain XCPMain XceedPro Main Menu 6 XCPMain Button Xceed XCP ToSpot SpecialNext Begin XceedPro Training 7 XCPMain Button Xceed XCP menu Review Review Specific Topics 8 XCP Title Xceed XCP menu POCCTPostTest XCPMain XceedPro Main Menu 9 XCP Button Xceed XCP ToSpot SpecialNext Begin XceedPro Training 10 XCP Button Xceed XCP menu Review Review Specific Topics 11 XCP Button Xceed XCP ToSpot SpecialTest Competency Test 12 XCP Title Xceed XCP menu Review XCPMain Review XceedPro Topics 13 XCP Button Xceed XCP ToSpot Parts Parts of XceedPro 14 XCP Button Xceed XCP ToSpot Operation Operation 15 XCP Button Xceed XCP ToSpot Trouble Troubleshooting 16 XCP Button Xceed XCP ToSpot Compare Comparison of XceedPro and Precision PCx 17 XCP Title Xceed XCP menu Operation Review Operation 18 XCP Button Xceed XCP ToSpot Sample Sample Collection 19 XCP Button Xceed XCP ToSpot Capillary Capillary Blood Samples segment 20 XCP Button Xceed XCP ToSpot Arterial Arterial Blood Samples 21 XCP Button Xceed XCP ToSpot Venous Venous Blood Samples Section 22 XCP Button Xceed XCP ToSpot PatientTest Patient Test 23 XCP Button Xceed XCP ToSpot PatientID Patient ID Confirmation 24 XCP Button Xceed XCP ToSpot Control Control Test 25 XCP Button Xceed XCP ToSpot DataReview Data Review 26 XCP Title Xceed XCP menu Trouble Review Operation 27 XCP Button Xceed XCP ToSpot TS-PatientTest Troubleshooting Patient Test 28 XCP Button Xceed XCP ToSpot TS-Control Troubleshooting Control Test 29 XCP Title Xceed XCP menu Parts Review Parts of XceedPro 30 XCP Button Xceed XCP ToSpot Keypad Keypad 31 XCP Button Xceed XCP ToSpot Barcode Barcode Scanner 32 XCP Button Xceed XCP ToSpot DataPort Data Port 33 XCP Button Xceed XCP ToSpot Battery Battery Compartment 34 XCP Button Xceed XCP ToSpot Port Port Protector 35 XCP Button Xceed XCP ToSpot TestStrip Test Strip 36 XCP Button Xceed XCP ToSpot Cleaning Cleaning 37 XCP Button Xceed XCP ToSpot Isolation Isolation Bags 38 XCP Admin Xceed Keypad admin Admin 933 POCCT Administration Menu 39 XCP Special Xceed special SpecialNext SpecialNext 40 XCP Special Xceed special SpecialTest SpecialTest 41 XCP Title PatientTest video PatientTest LESSON-143 867 Patient Test 42 XCP Body 3400 To Perform a Patient Test: 43 XCP Body 9000 Press the On-Off button to turn on the monitor. 44 XCP Body 14000 Select 1 - Patient Test. 45 XCP Body 18800 Scan or enter the Operator ID. 46 XCP Body 25867 To scan an ID, hold the monitor 3 to 12 inches from the barcode. 47 XCP Body 31533 Scan or enter the Patient ID. 48 XCP Body 35400 Now, Scan the test strip barcode. 49 XCP Body 48200 If you are manually entering the test strip lot number, use the keypad to enter the number located on the barcode label, then press enter. 50 XCP Body 52600 If prompted, select the sample type. 51 XCP Body 60867 Open the foil test strip packet at the notch and tear down to remove the test strip. 52 XCP Body 69000 Insert the strip with the contact bars facing the monitor. 53 XCP Body 74800 Apply the blood sample to the target area of the test strip. 54 XCP Body 82267 Do not allow blood to run down the test strip into the port. Do not lift the monitor to view the display until after the test strip has been removed. 55 XCP Body 92467 The monitor displays the test result after the countdown is completed. 56 XCP Body 98733 You may see additional post-testing prompts, such as Comment Code or Free Text entry. 57 XCP Body 100800 Scan or enter this information if prompted. 58 XCP Body 110600 Once the result is displayed, remove the test strip from the monitor and discard it as required by your facility's biohazard policy. 59 XCP Body 125067 If a test result is outside the defined Action Range, the result will appear with a triangle pointing up for above or pointing down for below the range. 60 XCP Body 136467 If a test result is outside of the defined Critical Range, the result will appear with a greater than or less than symbol. 61 XCP Body 142533 Refer to your institution's policy for handling out-of-range test results. 62 XCP QuesSetup Clipboard QuesSetup topic Now I would like to ask you some questions to make sure I have explained this clearly. 63 XCP Question POCAT-Q1 question Is it OK to let blood run down the test strip into the port? 64 XCP Touch Touch Please touch your answer. 65 XCP Answer Yes PatientTest Yes 66 XCP Answer-R No SpecialNext No 67 XCP Answer NotSure PatientTest Not Sure 68 XCP Title PatientID video PatientID LESSON-183 467 Patient ID Confirmation 69 XCP Body 9933 When running a Patient Test you may receive an additional prompt to confirm the patient's ID number. 70 XCP Body 15867 This prompt will appear after the initial Patient ID entry screen. 71 XCP Body 21933 To Perform a Patient Test with a patient ID confirmation screen enabled: 72 XCP Body 27000 Press the On-Off button to turn on the monitor. 73 XCP Body 31800 Select 1 - Patient Test. 74 XCP Body 37133 Scan or enter the Operator ID. 75 XCP Body 40867 Scan or enter the Patient ID. 76 XCP Body 45333 After the initial entry, you will be prompted to confirm the Patient ID. 77 XCP Body 52333 You may see one of the following three screens: 78 XCP Body 56400 Repeat Manual ID Entry Screen 79 XCP Body 62333 Re-enter the Patient ID using the Keypad to confirm the patient's ID. 80 XCP Body 65000 Confirm Patient ID Entry Screen 81 XCP Body 73400 Press 2 to confirm the Patient ID and continue testing or 1 to re-enter the ID. 82 XCP Body 77400 Confirm Patient's Year of Birth Entry Screen 83 XCP Body 84733 Enter the patient's year of birth to confirm the Patient ID or press clear to re-enter the ID. 84 XCP Body 95333 If you are prompted with a message Patient Data Not Found, the monitor either cannot confirm the Patient ID entered or the patient ID entered is not on the monitor's patient list. 85 XCP Body 99267 Press 1 to Re-Enter and confirm the patient ID. 86 XCP Body 115533 Once you have successfully confirmed the patient's ID you will be prompted to Scan the test strip barcode. 87 XCP Body 119933 If prompted, select the sample type. 88 XCP Body 130667 Open the foil test strip packet at the notch and tear down to remove the test strip. 89 XCP Body 137200 Insert the strip with the contact bars facing the monitor. 90 XCP Body 145000 Apply the blood sample to the target area of the test strip. 91 XCP Body 152867 Remember, do not allow blood to run down the test strip into the port. 92 XCP Body 161733 The monitor displays the test result after the countdown is completed. 93 XCP Body 170200 You may see additional post-testing prompts, such as Comment Code or Free Text entry. 94 XCP Body 177000 Scan or enter this information if prompted. 95 XCP Body 183000 Once the result is displayed, remove the test strip from the monitor and discard it as required by your facility's biohazard policy. 96 XCP QuesSetup Clipboard QuesSetup topic Now I would like to ask you some questions to make sure I have explained this clearly. 97 XCP Question POCAT-Q2 question Do you have to enter both an Operator ID and a Patient ID to start a test? 98 XCP Touch Touch Please touch your answer. 99 XCP Answer-R Yes SpecialNext Yes 100 XCP Answer No PatientID No 101 XCP Answer NotSure PatientID Not Sure 102 XCP Title Xceed Parts-1 topic Parts of the XceedPro 103 XCP Title Keypad video Keypad LESSON-63 933 Keypad 104 XCP Body 11933 Use the keypad to enter identification numbers and letters or to select an option that appears on the display. 105 XCP Body 21933 The keypad contains a 10 digit telephone-style keypad with keys for the numbers zero through 9. 106 XCP Body 30200 Buttons 2 through 9 also have letters below the number for entering alphabetical characters. 107 XCP Body 36333 To enter upper case characters, press the alphanumeric button. 108 XCP Body 42467 Press this button twice to enter lowercase characters. 109 XCP Body 47667 And press again to return to entering numbers. 110 XCP Body SpecialNext 62500 The keypad also has six special keys - a scan, on/off, backlight/alphanumeric, clear, menu, and enter. 111 XCP Title Barcode video Barcode LESSON-34 1600 Barcode Scanner 112 XCP Body 12533 To Scan, hold the monitor 3 to 12 inches from the barcode - at an angle from 30 to 135 degrees to the barcode. 113 XCP Body 22000 Press and hold the scan button until a visible red beam is emitted by the monitor. 114 XCP Body 30400 Slowly move the monitor, if necessary, so the red beam is directly over the barcode. 115 XCP Body SpecialNext 33533 The monitor will beep when the scan is complete. 116 XCP Title DataPort video DataPort LESSON-18 933 Data Port 117 XCP Body 7533 The Data Port is located on the bottom of the monitor. 118 XCP Body SpecialNext 18033 This port enables the monitor to automatically transfer the data through a cable or docking station to the data management system. 119 XCP Title Battery video Battery 333 Battery Compartment 120 XCP Body 9933 The monitor is powered by two AA batteries that go in the rear compartment. 121 XCP Body 15933 Two nickel-metal hydride (NiMH) rechargeable batteries may also be used. 122 XCP Body 22200 To prolong the battery life, the monitor should be turned off when not in use. 123 XCP Body SpecialNext 29533 Note that stored data is not affected if the batteries are removed. 124 XCP Title Port video Port LESSON-36 333 Port Protector 125 XCP Body 11400 The port protector helps keep liquid from entering the test strip port and damaging the monitor. All tests must be performed with the port protector in place. 126 XCP Body 17200 Replace the protector if it comes in contact with blood or control solution. After cleaning, dry the protector thoroughly. 127 XCP Body 22933 When replacement is necessary, lift the protector from the left or right edge and gently pull away. 128 XCP Body 31067 Then rest the flat bottom of the new protector on the test strip port and press gently into place on both sides. 130 XCP Title TestStrip video TestStrip LESSON-77 467 Test Strip 131 XCP Body 9933 The Precision XceedPro monitor is compatible with Precision PCx Plus Blood Glucose Test Strips. 132 XCP Body 17533 Precision PCx Plus Test Strips come in a gold foil packet with a barcode label. 133 XCP Body 29067 The individual foil packet ensures the integrity of each test strip by protecting it from exposure to air, moisture, and accidental contamination. 134 XCP Body 40533 The bar code label holds information about the test strip, including the lot number, calibration, expiration date, and expected control solution ranges. 135 XCP Body 48467 One quick scan sends all this information to the monitor at the time of the test. 136 XCP Body 56667 To open the foil packet, grasp it at the notch, tear down, and remove the test strip. 137 XCP Body 65067 The test strip is designed for either top-fill or end-fill sample application. 138 XCP Body SpecialNext 76533 Insert the contact bars into the monitor first, then apply blood or control solution to the target area at the other end of the test strip. 139 XCP Title Cleaning video Cleaning LESSON-27 467 Cleaning 140 XCP Body 11400 Clean the monitor by wiping it with a damp cloth or sponge moistened with a mild detergent. 141 XCP Body 18267 Please refer to the Operator's Manual for a list of approved cleaning solutions. 142 XCP Body SpecialNext 26533 Do not spray cleaner directly onto the monitor or allow liquid to drip into the strip port. 143 XCP Title Isolation video Isolation LESSON-13 333 Isolation Bags 144 XCP Body 5800 Disposable plastic isolation bags are available to provide a partial barrier between the monitor and patients in isolation. 145 XCP Body SpecialNext 12533 Insert the monitor into the bag so the strip port aligns with the hole, and seal the opposite end. 146 XCP Title Sample video Sample LESSON-165 733 Sample Collection 147 XCP Body 7867 The following are Operating Guidelines for tests using all sample types. 148 XCP Body 15333 Use only Precision PCx Plus Test Strips with the Precision XceedPro Monitor. 149 XCP Body 25867 For specific directions on storage and use of the test strips, refer to the package insert in the test strip box. 150 XCP Body 35867 Do not use the test strips beyond the expiration date printed on the barcode label and outer box. 151 XCP Body 41867 Do not use wet, bent, scratched or damaged test strips. 152 XCP Body 47467 Always use test strips immediately after opening the foil packet. 153 XCP Body 54000 Do not use test strips if the foil has a puncture or tear. 154 XCP Body 59467 Use the test strip only once, and then discard it. 155 XCP Body 69867 Use only control solutions listed on the test strip package insert to verify the performance of the Precision XceedPro System. 156 XCP Body 80333 Do not scan a packet's barcode and use a test strip from another packet. This could generate incorrect test results. 157 XCP Body 86200 Make sure the monitor and test strips are at room temperature. 158 XCP Body 96467 If the monitor is moved to a warmer or cooler area, allow the monitor to reach the new room temperature. 159 XCP Body 106867 Always wear gloves. And follow your facility's biohazard safety policies and procedures when performing tests involving patient blood samples. 160 XCP Body 114867 Fill the entire target area of the test strip with the blood sample. 161 XCP Body 126467 The test results will not be affected if the target area has been briefly touched with the patient's finger, a capillary tube or pipette. 162 XCP Body 137333 After the blood has been applied to the test strip and the test countdown begins, do not remove or disturb the test strip. 163 XCP Body 145467 If the test fails to start, quickly apply a second drop of blood to the target area. 164 XCP Body 155933 If the test fails to start after the second drop is applied, discard the used test strip and repeat the test. 165 XCP Body 165000 The allowable time limit to add a second drop of blood can be found in the test strip package insert. 166 XCP Title Capillary video Capillary SpecialNext LESSON-55 400 Capillary Blood Samples segment 167 XCP Body 5867 The following guidelines apply to tests using Capillary Blood Samples 168 XCP Body 9733 Use only fresh whole blood samples. 169 XCP Body 20000 Clean and completely dry the puncture site. Make sure the sampling site is clean and dry before lancing. 170 XCP Body 30133 Collect the capillary blood using a lancing device and an appropriate technique. 171 XCP Body 42800 Apply a drop of blood to the target area at the end of the test strip. Allow the entire target area to fill with blood. 172 XCP Body SpecialNext 55033 If necessary, the blood can be collected in a capillary tube coated with heparin or EDTA then applied to the test strip within 30 minutes of collection. 173 XCP Title Arterial video Arterial LESSON-67 733 Arterial Blood Samples 174 XCP Body 6333 The following guidelines apply to tests using Arterial Blood Samples: 175 XCP Body 10600 Use only fresh whole blood samples. 176 XCP Body 18333 Clear the arterial line before drawing a blood sample into the heparinized syringe. 177 XCP Body 22933 Use the sample within 30 minutes of collection. 178 XCP Body 40733 Immediately before applying the sample to the target area, mix the sample well by rolling the syringe between outstretched palms of both hands for at least 5 seconds; invert the syringe and repeat mixing. 179 XCP Body 46000 Allow a drop of blood to form at the tip of the syringe. 180 XCP Body 59533 Apply a drop of blood to the target area at the end of the test strip. Allow the entire target area to fill with blood. 181 XCP Body SpecialNext 67033 The syringe can briefly touch the test strip without affecting the test result. 182 XCP Title Venous video Venous LESSON-96 867 Venous Blood Samples Section 183 XCP Body 6467 The following guidelines apply to tests using Venous Blood Samples. 184 XCP Body 10333 Use only fresh whole blood samples. 185 XCP Body 18067 Collect the venous blood sample in a collection tube containing heparin or EDTA. 186 XCP Body 26067 Make sure the test tube is filled to the volume specified. Do not under-fill. 187 XCP Body 32133 Do not use collection tubes that contain fluoride or oxalate. 188 XCP Body 44400 If the blood is collected from an intravenous line, clear the line before drawing the sample into a syringe that contains heparin or EDTA. 189 XCP Body 48933 Use the sample within 30 minutes of collection. 190 XCP Body 57667 Immediately invert the tube with the sample several times before removing the sample. 191 XCP Body 66467 Use a disposable transfer pipette to obtain a sample from the center of the collection tube. 192 XCP Body 72400 Apply the drop of blood to the end of the test strip. 193 XCP Body 90067 If you are prompted to 'Enter Sample Type' when using the Precision PCx Plus Test Strip, use venous mode only for venous samples that have been in capped tubes and have not been mixed with air. 194 XCP Body SpecialNext 96033 Use capillary mode for all other samples. 195 XCP Title Control video Control LESSON-101 1267 Control Test 196 XCP Body 3867 To Perform a Control Test 197 XCP Body 9467 Press the on-Off button to turn on the monitor. 198 XCP Body 13667 Select Two - Control Test. 199 XCP Body 18067 Scan or enter the Operator ID 200 XCP Body 23400 Scan or enter the control Solution Lot number. 201 XCP Body 29133 Scan or enter the test strip lot number. 202 XCP Body 37733 Open the foil test strip packet at the notch, tear down, and remove the test strip. 203 XCP Body 44533 Insert the Strip with the contact bars facing the monitor. 204 XCP Body 49733 Wipe the control solution nozzle with a clean gauze or tissue. 205 XCP Body 57867 Then apply a small drop of solution to the test strip target area. 206 XCP Body 66333 Do not allow control solution to run down the test strip into the port 207 XCP Body 74067 Do not lift the monitor to view the display until after the test strip has been removed. 208 XCP Body 83467 The monitor displays the test result after the countdown is completed. 209 XCP Body 89800 Results may be displayed as a number or as Pass/Fail. 210 XCP Body 101333 If the control result is a number, an 'X' appears in front of a result that is out of range. 211 XCP Body SpecialNext 106833 If prompted, enter a comment code. 212 XCP Title DataReview video DataReview LESSON-62 667 Data Review 213 XCP Body 5733 There are two ways to review test data: 214 XCP Body 16067 Review a patient's result history after completing test or view test results through the Data Review menu option. 215 XCP Body 24667 Upon completion of a patient test you will be prompted with an option to view Patient History. 216 XCP Body 32200 Select 2 - Patient History to view the test result history of the patient just tested. 217 XCP Body 42533 To view test result through the Data Review menu option, select the Menu button on the keypad. 218 XCP Body 47733 Select 1 - Data Review. Scan or enter your Operator ID if prompted. 219 XCP Body SpecialNext 61500 Then select the desired data review option from the sub-menu. 220 XCP Title Compare video Compare LESSON-130 600 Comparison Chapter 221 XCP Body 11933 Users of the Abbott Diabetes Care Precision XceedPro may also be familiar with the Abbott Diabetes Care Precision PCx Blood Glucose Monitoring System. 222 XCP Body 23800 The following section provides a side by side comparison of the Precision XceedPro and the Precision PCx Blood Glucose Monitors. 223 XCP Body 29933 The Precision XceedPro monitor is similar to Abbott's Precision PCx Blood Glucose monitor. 224 XCP Body 35400 It builds on that proven success - providing all the same features. 225 XCP Body 40867 You see the same ergonomic design, for hand-held comfort. 226 XCP Body 48333 In both, the Test Strip Port is located at the top of the monitor. 227 XCP Body 54267 Both have a large, clear LCD screen - for accurate viewing. 228 XCP Body 59400 The scan button is at the top of the keypad. 229 XCP Body 64867 The Data Port is on the bottom of the monitor. 230 XCP Body 70467 The battery compartment is on back of the monitor. 231 XCP Body 75800 There's an integrated barcode scanner. 232 XCP Body 86000 You can even use the familiar gold foiled Precision PCx Plus Blood Glucose Test Strips with the Precision XceedPro monitor. 233 XCP Body 93533 And the method of applying blood samples and test solutions is also the same. 234 XCP Body 99267 All the same great features - with a few new enhancements. 235 XCP Body 112333 A Port Protector has been added to the test strip port to help keep liquid from entering the test strip port and damaging the monitor. 236 XCP Body 119400 An alphanumeric button has been added to the keypad to support additional data entry options. 237 XCP Body SpecialNext 130033 The Clear, Menu and Enter keys were relocated to the top of the keypad for improved ease of use. 238 XCP Title TS-PatientTest video TS-PatientTest 1686 Troubleshooting Patient Test 239 XCP Body 3148 Troubleshooting Patient Test Results 240 XCP Body 8164 Important: If the blood glucose result appears to be inconsistent - either lower or higher than expected - there may be a problem with the test strip. 241 XCP Body 17255 Repeat the test using a new test strip. 242 XCP Body 20650 Results that are incorrect may have serious medical consequences. 243 XCP Body 30995 Consult the prescribing physician before making any changes to diabetes medication plans if either of the following occurs: 244 XCP Body 36115 The blood glucose results are not consistent with the physical symptoms AND you have ruled out common errors in technique. 245 XCP Body 45780 or The blood glucose result is less than 50 milligrams per deciliter (2.8 millimoles per liter) or greater than 300 milligrams per deciliter (16.7 millimoles per liter). 246 XCP Body 50744 Possible reasons why glucose results may be higher than expected: 247 XCP Body 55890 The patient's hematocrit is lower than the acceptable limit for the test strips, as indicated on the test strip package insert. 248 XCP Body 59756 Serum or plasma samples were used instead of whole blood. 249 XCP Body 65215 Possible reasons why glucose results may be lower than expected: 250 XCP Body 70623 The patient's hematocrit is higher than the acceptable limit for the test strips, as indicated on the test strip package insert. 251 XCP Body 75064 The patient is in a Hyperglycemic-hypersomolar state - with or without ketosis. 252 XCP Body 77963 The patient is experiencing severe dehydration, hypotension or shock. 253 XCP Body 86636 There is water or alcohol remaining on the puncture site. 254 XCP Body 91338 The venous or arterial whole blood sample was not tested within 30 minutes of collection. 255 XCP Body SpecialNext 99132 For more detailed information, please refer to the appropriate test strip package insert. 256 XCP Title TS-Control video TS-Control 901 Troubleshooting Control Test 257 XCP Body 8509 To Troubleshoot Out-of-Range Control test results, repeat the control test to make sure you meet the following conditions. 258 XCP Body 16350 Eliminate any air bubbles in the control bottle's nozzle. 259 XCP Body 25492 Wipe away excess solution from the bottle tip prior to testing. 260 XCP Body 34101 Scan or enter the barcode from the packet of the test strip used. 261 XCP Body 43810 Scan or enter the correct lot number for the control solution used. 262 XCP Body 47080 Check the storage temperature of materials. 263 XCP Body 52753 Control solutions and test strips must be stored at temperatures between 39 degrees and 86 degrees Fahrenheit or 4 degrees and 30 degrees Celsius. 264 XCP Body 61361 Check that the temperature conditions in the room where the tests are being performed are within the acceptable operating range as specified in the test strip package insert. 265 XCP Body 69636 Check that the bottles of control solution have not been open for more than 90 days. 266 XCP Body 78579 Use a new test strip for each test. 267 XCP Body 87888 Use only PCx Plus Test Strips. 268 XCP Body 97231 Use only MediSenseŽ, PrecisionŽ or Optium Control Solutions. 269 XCP Body SpecialNext 110043 If the above criteria are met and the test results are still out of range, please repeat the test using a new box of control solution and/or test strips. 270 ACT TestQuestion ACT-Q1 question CT-1 Control A bottle of control solution is opened today, when will this bottle expire? 271 ACT Touch Touch Control Please touch your answer. 272 ACT Answer ACT-Q1A1 SpecialTest Control The expiration date on the bottle 273 ACT Answer ACT-Q1A2 SpecialTest Control 90 days after the bottle is opened 274 ACT Answer ACT-Q1A3 SpecialTest Control The expiration date established by the laboratory 275 ACT Answer-R ACT-Q1A4 SpecialTest Control 90 days after the bottle is opened or the expiration date, whichever comes first 276 ACT TestQuestion ACT-Q2 question CT-2 PatientTest By scanning the Test Strip, what information is captured? 277 ACT Touch Touch PatientTest Please touch your answer. 278 ACT Answer ACT-Q2A1 SpecialTest PatientTest Test Strip Lot Number 279 ACT Answer ACT-Q2A2 SpecialTest PatientTest Test Strip Lot Expiration Date 280 ACT Answer ACT-Q2A3 SpecialTest PatientTest Calibration Code 281 ACT Answer ACT-Q2A4 SpecialTest PatientTest Quality Control Ranges 282 ACT Answer-R ACT-Q2A5 SpecialTest PatientTest All of the Above 283 ACT TestQuestion ACT-Q3 question CT-3 Compare Which feature is available on the the Precision XceedPro that was not on the Precision PCx? 284 ACT Touch Touch Compare Please touch your answer. 285 ACT Answer ACT-Q3A1 SpecialTest Compare Laser Barcode Scanner 286 ACT Answer ACT-Q3A2 SpecialTest Compare Low Battery Warning 287 ACT Answer-R ACT-Q3A5 SpecialTest Compare Port Protector 288 ACT Answer ACT-Q3A3 SpecialTest Compare Clear and Menu Keys 289 ACT Answer ACT-Q3A4 SpecialTest Compare Patient and Control Testing Prompts 290 ACT TestQuestion ACT-Q4 question CT-4 PatientTest How many Patient Test Records can be stored in the memory of the Precision Xceed Pro meter? 291 ACT Touch Touch PatientTest Please touch your answer. 292 ACT Answer ACT-Q4A1 SpecialTest PatientTest 100 293 ACT Answer ACT-Q4A2 SpecialTest PatientTest 500 294 ACT Answer ACT-Q4A3 SpecialTest PatientTest 1000 295 ACT Answer ACT-Q4A4 SpecialTest PatientTest 2000 296 ACT Answer-R ACT-Q4A5 SpecialTest PatientTest 2500 297 ACT TestQuestion ACT-Q5 question CT-5 Sample How do you know if you have applied enough blood to the test strip of the Precision Xceed Pro? 298 ACT Touch Touch Sample Please touch your answer. 299 ACT Answer ACT-Q5A1 SpecialTest Sample You must check the strip visually. 300 ACT Answer ACT-Q5A2 SpecialTest Sample You will not know if you have enough sample for the test. 301 ACT Answer ACT-Q5A3 SpecialTest Sample You see the screen change to apply blood. 302 ACT Answer ACT-Q5A4 SpecialTest Sample You will see the blood turn purple on the test strip. 303 ACT Answer-R ACT-Q5A5 SpecialTest Sample You will hear an audible beep and the testing will automatically start. 304 ACT TestQuestion ACT-Q6 question CT-6 Sample What are some reasons a blood glucose test may be higher than expected? 305 ACT Touch Touch Sample Please touch your answer. 306 ACT Answer ACT-Q6A1 SpecialTest Sample 307 ACT Answer ACT-Q6A2 SpecialTest Sample 308 ACT Answer ACT-Q6A3 SpecialTest Sample 309 ACT Answer ACT-Q6A4 SpecialTest Sample 310 ACT Answer-R ACT-Q6A5 SpecialTest Sample 311 ACT TestQuestion ACT-Q7 question CT-7 PatientTest What are you expected to do when the Precision XceedPro prompts you to Scan or Enter Operator ID? 312 ACT Touch Touch PatientTest Please touch your answer. 313 ACT Answer ACT-Q7A1 SpecialTest PatientTest Scan the test strip barcode. 314 ACT Answer ACT-Q7A2 SpecialTest PatientTest Type in the Patients Name. 315 ACT Answer ACT-Q7A3 SpecialTest PatientTest Scan the Patients wrist band. 316 ACT Answer-R ACT-Q7A5 SpecialTest PatientTest Scan or type in my ID number. 317 ACT Answer ACT-Q7A4 SpecialTest PatientTest Enter in the calibration code. 318 ACT TestQuestion ACT-Q8 question CT-8 Battery The Precision XceedPro meter will display a Battery Symbol indicating the batteries are running low. 319 ACT Touch Touch Battery Please touch your answer. 320 ACT Answer-R ACT-Q8A1 SpecialTest Battery TRUE 321 ACT Answer ACT-Q8A2 SpecialTest Battery FALSE 322 ACT TestQuestion ACT-Q9 question CT-9 Sample Blood should never be applied to the Precision Xceed Test Strip until the strip is inserted into the meter and the display reads, Apply Sample. 323 ACT Touch Touch Sample Please touch your answer. 324 ACT Answer-R ACT-Q9A1 SpecialTest Sample TRUE 325 ACT Answer ACT-Q9A2 SpecialTest Sample FALSE 326 ACT TestQuestion ACT-Q10 question CT-10 Control Quality Control Testing should be performed before every patient test. 327 ACT Touch Touch Control Please touch your answer. 328 ACT Answer ACT-Q10A1 SpecialTest Control TRUE 329 ACT Answer-R ACT-Q10A2 SpecialTest Control FALSE 330 ACT TestQuestion ACT-Q11 question CT-11 Barcode What is the best way to scan a barcode using the Precision Xceed Pro? 331 ACT Touch Touch Barcode Please touch your answer. 332 ACT Answer ACT-Q11A1 SpecialTest Barcode Hold the Scan button and aim Precision scanner at a 90 degree angle to the barcode? 333 ACT Answer ACT-Q11A2 SpecialTest Barcode Press the scan button, release it and scan the barcode from paper. 334 ACT Answer ACT-Q11A3 SpecialTest Barcode Press and hold the enter button, while scanning the barcode. 335 ACT Answer-R ACT-Q11A5 SpecialTest Barcode 3-6 inches from the barcode, slowly scan the barcode with the red beam until you hear a beep. 336 ACT TestQuestion ACT-Q12 question CT-12 Compare The Precision Xceed ProŽ Plus blood glucose test strip is designed to allow which of the following: 337 ACT Touch Touch Compare Please touch your answer. 338 ACT Answer ACT-Q12A1 SpecialTest Compare Top Fill Sample application 339 ACT Answer ACT-Q12A2 SpecialTest Compare End Fill sample application 340 ACT Answer ACT-Q12A3 SpecialTest Compare Neither Top fill or End fill 341 ACT Answer-R ACT-Q12A5 SpecialTest Compare Both Top Fill and End Fill sample application 342 ACT TestQuestion ACT-Q13 question CT-13 Port If blood or control solution comes in contact with the port protector, you should you replace port protector prior to testing. 343 ACT Touch Touch Port Please touch your answer. 344 ACT Answer-R ACT-Q13A1 SpecialTest Port TRUE 345 ACT Answer ACT-Q13A2 SpecialTest Port FALSE 346 ACT TestQuestion ACT-Q14 question CT-14 Keypad How do you backup one space while entering numbers on the keypad? 347 ACT Touch Touch Keypad Please touch your answer. 348 ACT Answer-R ACT-Q14A5 SpecialTest Keypad Press the CLEAR key 349 ACT Answer ACT-Q14A1 SpecialTest Keypad Press the DELETE key 350 ACT Answer ACT-Q14A2 SpecialTest Keypad Press the ENTER key 351 ACT Answer ACT-Q14A3 SpecialTest Keypad Press the SCAN key 352 ACT Answer ACT-Q14A4 SpecialTest Keypad Shut the meter OFF 353 ACT TestQuestion ACT-Q15 question CT-15 PatientTest When can Patient test result history be recalled on the Precision XceedPro meter? 354 ACT Touch Touch PatientTest Please touch your answer. 355 ACT Answer ACT-Q15A1 SpecialTest PatientTest Before the test strip is scanned. 356 ACT Answer ACT-Q15A2 SpecialTest PatientTest After the test strip is scanned 357 ACT Answer ACT-Q15A3 SpecialTest PatientTest Patient test history cannot be recalled on the Precision XceedPro meter. 358 ACT Answer-R ACT-Q15A5 SpecialTest PatientTest Either before the a test is run using Data Review or after a test is run using Patient History selections. 359 ACT TestQuestion ACT-Q16 question CT-16 PatientTest Where can you find information to troubleshoot a patient or control test result that is out of range? 360 ACT Touch Touch PatientTest Please touch your answer. 361 ACT Answer ACT-Q16A1 SpecialTest PatientTest Opertor's Manual 362 ACT Answer ACT-Q16A2 SpecialTest PatientTest Abbott Technical Support 363 ACT Answer ACT-Q16A3 SpecialTest PatientTest Precision XceedPro Quick Reference Guide 364 ACT Answer ACT-Q16A4 SpecialTest PatientTest Precision XceedPro Test Strip package insert 365 ACT Answer-R ACT-Q16A5 SpecialTest PatientTest All of the above 366 ACT TestQuestion ACT-Q17 question CT-17 Cleaning Is it OK to use alcohol and ammonia based cleaners for cleaning the Precision Xceed Pro monitor? 367 ACT Touch Touch Cleaning Please touch your answer. 368 ACT Answer-R ACT-Q17A1 SpecialTest Cleaning TRUE 369 ACT Answer ACT-Q17A2 SpecialTest Cleaning FALSE 370 ACT TestQuestion ACT-Q18 question CT-18 Isolation How can you use the Precision XceedPro meter with a patient on isolation? 371 ACT Touch Touch Isolation Please touch your answer. 372 ACT Answer ACT-Q18A1 SpecialTest Isolation Dedicate one Precision XceedPro meter to the isolation patient. 373 ACT Answer ACT-Q18A2 SpecialTest Isolation Use a Protex isolation bag or cover the PXP meter using a bag prior to inserting strip 374 ACT Answer ACT-Q18A3 SpecialTest Isolation Clean the surfaces of the Precision XceedPro Meter in between each patient 375 ACT Answer-R ACT-Q18A5 SpecialTest Isolation All of the above. 376 ACT TestQuestion ACT-Q19 question CT-19 Control What is expected if you receive the message, Unexpected Level when running a Control test on the Precision XceedPro meter? 377 ACT Touch Touch Control Please touch your answer. 378 ACT Answer ACT-Q19A1 SpecialTest Control Repeat the patient test 379 ACT Answer ACT-Q19A2 SpecialTest Control Open a new control solution bottle. 380 ACT Answer-R ACT-Q19A5 SpecialTest Control Select ReEnter Level and scan the level it is expecting. 381 ACT Answer ACT-Q19A3 SpecialTest Control Enter in the lot number of the test strip. 382 ACT Answer ACT-Q19A4 SpecialTest Control Scan the Patient's ID. 383 ACT TestQuestion ACT-Q20 question CT-20 Patient ID Can you enter in letters instead of numbers in the Precision XceedPro? 384 ACT Touch Touch Patient ID Please touch your answer. 385 ACT Answer ACT-Q20A1 SpecialTest Patient ID Yes, but you have to scan from a barcode. 386 ACT Answer ACT-Q20A2 SpecialTest Patient ID No 387 ACT Answer ACT-Q20A3 SpecialTest Patient ID Yes by using the Aa key only. 388 ACT Answer-R ACT-Q20A5 SpecialTest Patient ID Yes, by using the Aa key or scanning a barcode. 389 ACT TestQuestion ACT-Q21 question CT-21 PatientTest What happens if you mistakenly hit the On/Off button on the Precision XceedPro during testing? 390 ACT Touch Touch PatientTest Please touch your answer. 391 ACT Answer ACT-Q21A1 SpecialTest PatientTest It stops the test and shuts off. 392 ACT Answer ACT-Q21A2 SpecialTest PatientTest It displays a test error code 393 ACT Answer ACT-Q21A3 SpecialTest PatientTest The test will continue and then it shuts off automatically when the test is complete 394 ACT Answer-R ACT-Q21A5 SpecialTest PatientTest Nothing, you must press and hold the On/Off key for the meter to shut off. 395 ACT TestQuestion ACT-Q22 question CT-22 Sample What is the size of the blood sample required to atart a test using the Precision Plus test strips? 396 ACT Touch Touch Sample Please touch your answer. 397 ACT Answer ACT-Q22A1 SpecialTest Sample 1 ml 398 ACT Answer ACT-Q22A2 SpecialTest Sample .5 ml 399 ACT Answer ACT-Q22A3 SpecialTest Sample 2 cc's 400 ACT Answer ACT-Q22A4 SpecialTest Sample 5 microliters 401 ACT Answer-R ACT-Q22A5 SpecialTest Sample 2.5 microliters (???r) 402 ACT TestQuestion ACT-Q23 question CT-23 DataReview What button allows you to get to the Data Review option? 403 ACT Touch Touch DataReview Please touch your answer. 404 ACT Answer ACT-Q23A1 SpecialTest DataReview On/Off 405 ACT Answer ACT-Q23A2 SpecialTest DataReview CLEAR 406 ACT Answer ACT-Q23A3 SpecialTest DataReview ENTER 407 ACT Answer-R ACT-Q23A5 SpecialTest DataReview MENU 408 ACT Answer ACT-Q23A4 SpecialTest DataReview SCAN 409 ACT TestQuestion ACT-Q24 question CT-24 DataPort By placing the Precision XceedPro into the docking station, upload will begin automatically. 410 ACT Touch Touch DataPort Please touch your answer. 411 ACT Answer-R ACT-Q24A1 SpecialTest DataPort TRUE 412 ACT Answer ACT-Q24A2 SpecialTest DataPort FALSE 413 ACT TestQuestion ACT-Q25 question CT-25 DataPort What appears on the screen while a Precision XceedPro meter is uploading it's data? 414 ACT Touch Touch DataPort Please touch your answer. 415 ACT Answer ACT-Q25A1 SpecialTest DataPort Dock in Progress 416 ACT Answer ACT-Q25A2 SpecialTest DataPort QC Due Now 417 ACT Answer ACT-Q25A3 SpecialTest DataPort Patient Test or Control Test 418 ACT Answer ACT-Q25A4 SpecialTest DataPort Remove Strip 419 ACT Answer-R ACT-Q25A5 SpecialTest DataPort Please Wait Data Uploading 420 ACT TestQuestion ACT-Q26 question CT-26 TS-PatientTest What is the likely cause if you receive the error message, Strip Error Wet or Damaged? 421 ACT Touch Touch TS-PatientTest Please touch your answer. 422 ACT Answer-R ACT-Q26A5 SpecialTest TS-PatientTest The test strip is wet or has already been used. 423 ACT Answer ACT-Q26A1 SpecialTest TS-PatientTest The test strip barcode did not scan properly. 424 ACT Answer ACT-Q26A2 SpecialTest TS-PatientTest You have scanned or entered an expired strip. 425 ACT Answer ACT-Q26A3 SpecialTest TS-PatientTest The test strip is the wrong kind for the meter. 426 ACT TestQuestion ACT-Q27 question CT-27 PatientTest What is expected when the Precision XceedPro meter prompts you for the Patient Identification (ID)? 427 ACT Touch Touch PatientTest Please touch your answer. 428 ACT Answer ACT-Q27A1 SpecialTest PatientTest Follow procedures to obtain a lab sample. 429 ACT Answer ACT-Q27A2 SpecialTest PatientTest Scan the test strip barcode. 430 ACT Answer ACT-Q27A3 SpecialTest PatientTest Enter in the Control solution lot number. 431 ACT Answer ACT-Q27A4 SpecialTest PatientTest Press Enter to bypass the prompt. 432 ACT Answer-R ACT-Q27A5 SpecialTest PatientTest Scan or Enter in the Patient Idenifier as described in your procedures. 433 ACT TestQuestion ACT-Q28 question CT-28 PatientTest What action is required when the Precision XceedPro Meter displays, Operator Certification Expires in 10 days. 434 ACT Touch Touch PatientTest Please touch your answer. 435 ACT Answer ACT-Q28A1 SpecialTest PatientTest You have scanned the test strip barcode by mistake. Scan a new test strip. 436 ACT Answer ACT-Q28A2 SpecialTest PatientTest Try the test again later. 437 ACT Answer ACT-Q28A3 SpecialTest PatientTest No action is required, continue testing. 438 ACT Answer-R ACT-Q28A5 SpecialTest PatientTest Complete the test then, notify your supervisor/manager and obtain instructions for recertification. 439 ACT TestQuestion ACT-Q29 question CT-29 Port What type of batteries does the Precision XceedPro Accept? 440 ACT Touch Touch Port Please touch your answer. 441 ACT Answer ACT-Q29A1 SpecialTest Port One 9 Volt 442 ACT Answer ACT-Q29A2 SpecialTest Port Lithium Ion 443 ACT Answer ACT-Q29A3 SpecialTest Port Nickel Cadmium 444 ACT Answer ACT-Q29A4 SpecialTest Port Two C Batteries 445 ACT Answer-R ACT-Q29A5 SpecialTest Port Two AA Batteries